400W |

ATX 2.03,ATX12V(P4),EPS12V,WTX,AMD-GES |

Server,Workstation,Storage System,IPC,PCs |
|
|
|
|
 |
 |

140.00x150.00x86.00 (mm)
5.51x5.91x3.39 (inch) |
 |
|

VOLTAGE: 90 ~ 264 VAC FULL RANGE |
|
|
|
|
 |
| Output Voltage |
Output Current Min. |
Output Current Max. |
Output Current Peak |
Regulation Load |
Regulation Line |
Output Ripple & Noise Max.[P-P] |
| 5V |
3 |
35.00 |
|
± 5% |
± 1% |
50mV |
|
|
 |
| 12V |
2 |
30 |
|
+7% ~ -5% |
± 1% |
120mV |
|
|
 |
| +5VSB |
0.1 |
2 |
|
± 5% |
± 1% |
50mV |
|
|
 |
 |
| REMARKS: THE OUTPUT CURRENT OF 5V & 3.3V NOT EXCEED 45A |

*Active PFC ( full range )
*12V Max. Current : 30A
*Noise & Thermal Control ( Silence & Reliable )
*TEMPERATURE RANGE: OPERATING -10℃ --- 40℃
* HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95%
* REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS
*COOLING: ONE 80mm DC FAN
*ACTIVE POWER FACTOR CORRECTION MEET IEC-1000-3-2 CLASS D
*EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
*SAFETY: UL 1950, CSA 22.2 NO/ 950, TUV IEC 950
*Serial ATA optional
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS. |
| WHERE TO BUY |
| Online |
 |
 |
| |
|
|
|
|
 |
|
|
|
|
|
|
|

|
|
|
|