VOLTAGE: 90 ~ 264 VAC FULL RANGE
FREQUENCY: 47~63 HZ
INPUT CURRENT:10.0 A ( RMS ) FOR 115VAC /
5.0 A ( RMS ) FOR 230VAC
INRUSH CURRENT: 40A MAX. FOR 115 VAC /
60 A MAX. FOR 230 VAC
Output Voltage
Output Current Min.
Output Current Max.
Output Current Peak
Regulation Load
Regulation Line
Output Ripple & Noise Max.[P-P]
+5V
0.5
25.00
±5%
±1%
50mV
+12V
2
40
±5%
±1%
120mV
-12V
0
0.8
±5%
±1%
120mV
+3.3V
0.5
25
±5%
±1%
50mV
+5VSB
0.1
3.5
±5%
±1%
50mV
* TEMPERATURE RANGE: OPERATING 0℃ --- 50℃, STORAGE –20℃ --- 80℃
* HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
* EFFICIENCY: 80% TYPICAL AT 115V, FULL LOAD
* POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
* OVER POWER PROTECTION
* OVER VOLTAGE PROTECTION
* OVER CURRENT PROTECTION
* SHORT CIRCUIT PROTECTION
* EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
* SAFETY: TO MEET UL, CUL, TUV, CCC * 3.3V / 5V REMOTE SENSING
* COOLING: ONE 40mm DC FANS
* ACTIVE POWER FACTOR CORRECTION MEET IEC-1000-3-2 CLASS D
*THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.